{"tema_id":"483","string":"FrontTime","created":"2026-04-08 06:53:55","code":null,"notes":[{"@type":"Definition note","@lang":"en","@value":"High current impulse front time\nFor an exponential impulse current, 1.25 times the interval T, between the instants when the relative values of the pulse rise are reached.\nNote: typical relative values are between 10 % and 90 % of the peak value. "},{"@type":"Definition note","@lang":"de","@value":"Impulsstromstirnzeit\nVirtueller Parameter eines exponentiellen Stromimpulses definiert als das 1,25-fache des Intervalls zwischen zwei relativen Schwellwerten eines Pusanstiegs.\nBemerkung: typische relative Werte betragen 10 % und 90 % des Spitzenwerts. "},{"@type":"Scope note","@lang":"en","@value":"Unit: s "},{"@type":"Scope note","@lang":"en","@value":"DSI Unit: \\second "},{"@type":"Scope note","@lang":"en","@value":"SI Unit: s "},{"@type":"Historical note","@lang":"en","@value":"2026-04-08 Created "},{"@type":"Element note","@lang":"en","@value":"Electromagnetic.Current.Pulse.HighCurrent.FrontTime "},{"@type":"Bibliographic note","@lang":"en","@value":" "},{"@type":"Example note","@lang":"en","@value":" "}]}