{"tema_id":"555","string":"inhomogenity","created":"2026-05-22 08:24:26","code":null,"notes":[{"@type":"Definition note","@lang":"de","@value":"Information zur Inhomogenit\u00e4t des Kalibriergegenstands "},{"@type":"Definition note","@lang":"en","@value":"Information on the inhomogenity of the calibrated device "},{"@type":"Scope note","@lang":"de","@value":"Zwei separate  Elemente geben an, ob die Inhomogenit\u00e4t experimentell bestimmt oder nur gesch\u00e4tzt wurde sowie ob der Inhomogenit\u00e4tsbeitrag als Unsicherheit in der Messunsicherheitsbilanz ber\u00fccksichtigt wurde. Die DKD-R 5-3 fordert eine Ber\u00fccksichtigung in der Messunsicherheit, der entsprechende Eintreg muss immer true gesetzt sein. Beide Eintr\u00e4ge sind \u00fcber refTypes referenziert. Eine menschenlesbare Beschreibung der Metadaten ist optional (hier nicht aufgef\u00fchrt). "},{"@type":"Scope note","@lang":"en","@value":"Two separate  entries indicate whether inhomogenity was investigated experimentally, and whether contributions of inhomogenity are considered a part of the measurement uncertainty estimation. As DKD-R 5-3 requires inhomogenity to be included in uncertainty the relevant entry must be given true. "},{"@type":"Historical note","@lang":"en","@value":"2026-05-28 Created "},{"@type":"Bibliographic note","@lang":"en","@value":"DKD-R 5-3 "},{"@type":"Example note","@lang":"en","@value":"\n\u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 Einfluss der Inhomogenit\u00e4t\n\u00a0 \u00a0 \u00a0 \u00a0 Influence of inhomogenity\n\u00a0 \u00a0 \n\u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 Angegeben ist die Standardunsicherheit der Inhomogenit\u00e4t.\n\u00a0 \u00a0 \u00a0 \u00a0 The standard uncertainty of inhomogenity is stated.\n\u00a0 \u00a0 \n\u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 NaN\n\u00a0 \u00a0 \u00a0 \u00a0 \\kelvin\n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 0.17 0.18 0.13 0.12 0.11\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 normal\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \n\u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Bestimmung der Inhomogenit\u00e4t\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Determination of inhomogenity\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 DKD-R 5-3:2018-09\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 8.8\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 https:\/\/doi.org\/10.7795\/550.20231207\n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \n\u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Experimentelle Untersuchung der Inhomogenit\u00e4t f\u00fcr den Temperaturf\u00fchler:\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Experimential investigation of the influence of inhomogenity for the thermal sensor:\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 true\n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Der Einfluss der Inhomogenit\u00e4t ist in der angegebenen erweiterten Messunsicherheit enthalten.\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 The influence of inhomogenity is included in the expanded measurement uncertainty.\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 true\n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 true\n\u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \n "}]}