{"@context":{"dc":"http:\/\/purl.org\/dc\/elements\/1.1\/","skos":"http:\/\/www.w3.org\/2004\/02\/skos\/core#","skos:broader":{"@type":"@id"},"skos:inScheme":{"@type":"@id"},"skos:related":{"@type":"@id"},"skos:narrower":{"@type":"@id"},"skos:hasTopConcept":{"@type":"@id"},"skos:topConceptOf":{"@type":"@id"}},"@id":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/289","@type":"skos:Concept","skos:prefLabel":{"@language":"en-US","@value=":"inputValue"},"skos:inScheme":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/","dct:created":"2025-01-13 13:15:44","skos:definition":[{"@lang":"de","@value":"Eingangswert des Thermometerwiderstandes oder des Anzeigewertes "},{"@lang":"en","@value":"The input resistance value or displayed value of the probe "}],"skos:scopeNote":[{"@lang":"de","@value":"Der Eingangswert wird \u00fcblicherweise am Eispunkt oder am Wassertripelpunkt gemessen "},{"@lang":"en","@value":"The input value is commonly measured at the ice point or the water triple point "}],"skos:historyNote":[{"@lang":"en","@value":"Created "}],"skos:note":[{"@lang":"en","@value":"DKD-R 5-1 "}],"skos:example":[{"@lang":"en","@value":"\n\u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 Ergebnisse der Voruntersuchungen\n\u00a0 \u00a0 \u00a0 Results of the initial inspections\n\u00a0 \u00a0\n\u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Eingangswert\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Input value\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 100,0022\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \\ohm\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Bestimmung des Eingangswertes\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Determination of the inputValue\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Als Eingangswert wurde der F\u00fchlerwiderstand am Eispunkt gemessen.\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0  As the input value, the resistance of the probe was measured at the ice point.\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0DKD-R 5-1:2023-11\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a06\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0https:\/\/doi.org\/10.7795\/550.20231207\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0\n "}],"skos:broader":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/117"],"skos:related":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/290"]}