{"@context":{"dc":"http:\/\/purl.org\/dc\/elements\/1.1\/","skos":"http:\/\/www.w3.org\/2004\/02\/skos\/core#","skos:broader":{"@type":"@id"},"skos:inScheme":{"@type":"@id"},"skos:related":{"@type":"@id"},"skos:narrower":{"@type":"@id"},"skos:hasTopConcept":{"@type":"@id"},"skos:topConceptOf":{"@type":"@id"}},"@id":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/291","@type":"skos:Concept","skos:prefLabel":{"@language":"en-US","@value=":"insulationResistance"},"skos:inScheme":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/","dct:created":"2025-01-13 13:44:05","skos:definition":[{"@lang":"de","@value":"Isolationswiderstand der w\u00e4hrend der Kalibrierung bestimmt wurde "},{"@lang":"en","@value":"The insulation resistance that was determined during the calibration "}],"skos:scopeNote":[{"@lang":"de","@value":"Der Isolationswiderstand wird \u00fcblicherweise bei Raumtemperatur mit einer Spannung von mindestens 100 V und bei der h\u00f6chsten Kalibriertemperatur mit mindestens 10 V bestimmt. "},{"@lang":"en","@value":"Typically, the insulation resistance is determined at room temperature with a voltage of &gt;100 V and at the hingest calibration temperature with &gt;10 V. "},{"@lang":"de","@value":"Der Isolationswiderstand wird zwischen jedem Messkreis und der Armatur gemessen, angegeben wird typischerweise kleinste der gemessenen Werte. "},{"@lang":"en","@value":"The insulation resistance is measured between each measuring circuit and the fitting, typically only the smallest of these values is stated. "}],"skos:historyNote":[{"@lang":"en","@value":"Created "}],"skos:note":[{"@lang":"en","@value":"EN IEC 60751 "}],"skos:example":[{"@lang":"en","@value":"\n\u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 Ergebnisse der Voruntersuchungen\n\u00a0 \u00a0 \u00a0 Results of the initial inspections\n\u00a0 \u00a0\n\u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Minimaler Isolationswiderstand bei Raumtemperatur und h\u00f6chster Kalibriertemperatur\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 Minimum insulation resistance at room temperature and at the hingest calibration temperature\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 355 56\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \\mega\\ohm\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0\n\u00a0 \u00a0 \u00a0 \n\u00a0 \u00a0\n "}],"skos:broader":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/117"],"skos:related":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/290"]}