{"@context":{"dc":"http:\/\/purl.org\/dc\/elements\/1.1\/","skos":"http:\/\/www.w3.org\/2004\/02\/skos\/core#","skos:broader":{"@type":"@id"},"skos:inScheme":{"@type":"@id"},"skos:related":{"@type":"@id"},"skos:narrower":{"@type":"@id"},"skos:hasTopConcept":{"@type":"@id"},"skos:topConceptOf":{"@type":"@id"}},"@id":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/317","@type":"skos:Concept","skos:prefLabel":{"@language":"en-US","@value=":"calibrationMedium"},"skos:inScheme":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/","dct:created":"2025-07-03 20:24:13","skos:definition":[{"@lang":"en-US","@value":"Information on the substance in or with which the calibration was carried out \u00a0 and that was in touch with the calibration item (e.g. measuring tip) during the calibration. "},{"@lang":"de","@value":"Informationen \u00fcber die Substanz in oder mit der die Kalibrierung durchgef\u00fchrt wurde und die mit dem Kalibriergegenstand (z.B. Messspitze) w\u00e4hrend der Kalibrierung in Ber\u00fchrung war. "}],"skos:scopeNote":[{"@lang":"de","@value":"Beispiele f\u00fcr das Kalibriermedium k\u00f6nnen sein:\n\nFl\u00fcssigkeit in einem Temperierbad\nGas in dem ein Feuchtesensor kalibriert wurde\nK\u00fchlmedium in dem ein Referenzwiderstand w\u00e4hrend seiner Kalibrierung eingetaucht war\nFl\u00fcssigkeit mit der eine Pipettenkalibrierung durchgef\u00fchrt wurde\nDruck\u00fcbertragungsmedium mit dem die Kalibrierung eines Druckmessger\u00e4tes durchgef\u00fchrt wurde.\n "},{"@lang":"en-US","@value":"Some examples of a calibration medium are:\n\nliquid in a temperature calibration bath\ngas in which a humidity sensor was calibrated\ncooling medium in which a reference resitor was immersed during its calibration\nliquid that was used for the calibration of a pipette.\npressure-transmitting medium for the calibration of presssure gauges.\n "}],"skos:historyNote":[{"@lang":"en-US","@value":"2025-07-03 Created "},{"@lang":"en-US","@value":"2025-11-06 Added 3 XML examples "}],"skos:example":[{"@lang":"en-US","@value":"&lt;!-- Option 1: Angabe der CAS-Nr.\/ Specification of the CAS no. --&gt;\n&lt;dcc:measuringEquipment refType=\"basic_calibrationMedium\"&gt;\n\u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Kalibriermedium&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;Calibration medium&lt;\/dcc:content&gt;\n\u00a0 \u00a0 &lt;\/dcc:name&gt;\n\u00a0 \u00a0 &lt;dcc:equipmentClass&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:reference&gt;CAS Database&lt;\/dcc:reference&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:classID&gt;132259-10-0&lt;\/dcc:classID&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:link&gt;https:\/\/commonchemistry.cas.org\/&lt;\/dcc:link&gt;\n\u00a0 \u00a0 &lt;\/dcc:equipmentClass&gt;\n\u00a0 \u00a0 &lt;dcc:description&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Luft&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;air&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:name&gt;\n\u00a0 \u00a0 &lt;\/dcc:description&gt;\n&lt;\/dcc:measuringEquipment&gt; "},{"@lang":"en-US","@value":"&lt;!-- Option 2: Angabe feststehender Begriff, Erkl\u00e4rung in Expertenbericht (alternativ auch Norm etc. m\u00f6glich)\/ Specification of a fixed term, explanation in an export report (alternatively, a norm etc. is also possible)--&gt;\n&lt;dcc:measuringEquipment refType=\"basic_calibrationMedium\"&gt;\n\u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Kalibriermedium&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;dcc:content lang=\"en\"&gt;calibration medium&lt;\/dcc:content&gt;\n\u00a0 \u00a0 &lt;\/dcc:name&gt;\n\u00a0 \u00a0 \u00a0&lt;dcc:equipmentClass&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;dcc:reference&gt;DKD-E x-y&lt;\/dcc:reference&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:classID&gt;Nitrogen&lt;\/dcc:classID&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:link&gt;https:\/\/www.ptb.de\/cms\/metrologische-dienstleistungen\/dkd\/publikationen.html&lt;\/dcc:link&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;!-- Alternativ: Angabe DOI --&gt;\n\u00a0 \u00a0 \u00a0&lt;\/dcc:equipmentClass&gt;\n\u00a0 \u00a0 \u00a0&lt;dcc:description&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;dcc:content lang=\"de\"&gt;Luft&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;dcc:content lang=\"en\"&gt;air&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:name&gt;\n\u00a0 \u00a0 \u00a0&lt;\/dcc:description&gt;\n\u00a0&lt;\/dcc:measuringEquipment&gt; "},{"@lang":"en-US","@value":"&lt;!-- Option 3: Angabe eines verwendeten Materials (optional mit Zertifikat)\/ Specification of materials used (optionally with certificate) \u00a0--&gt;\n&lt;dcc:measuringEquipment refType=\"basic_calibrationMedium\"&gt;\n\u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Kalibriermedium&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;Calibration medium&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0&lt;\/dcc:name&gt;\n\u00a0 \u00a0 \u00a0&lt;dcc:description&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;dcc:content lang=\"de\"&gt;Luft&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;air&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0&lt;\/dcc:name&gt;\n\u00a0 \u00a0 &lt;\/dcc:description&gt;\n\u00a0 \u00a0 &lt;dcc:certificate&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:referral&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Kalibrierschein ohne Akkreditierungssymbol&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;CalibrationCertificate without accreditation symbol&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:referral&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:referralID&gt;BAM-202x-12345&lt;\/dcc:referralID&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:procedure&gt;analogue&lt;\/dcc:procedure&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:value&gt;analogue&lt;\/dcc:value&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:traceable&gt;false&lt;\/dcc:traceable&gt;\n\u00a0 \u00a0 &lt;\/dcc:certificate&gt;\n\u00a0 \u00a0 &lt;dcc:manufacturer&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Gashersteller&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;gas manufacturer&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:location&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:city&gt;Stadt&lt;\/dcc:city&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:location&gt;\n\u00a0 \u00a0 &lt;\/dcc:manufacturer&gt;\n\u00a0 \u00a0 &lt;dcc:identifications&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:identification&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:issuer&gt;calibrationLaboratory&lt;\/dcc:issuer&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:value&gt;123456&lt;\/dcc:value&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;interne Flaschennummer&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"en\"&gt;internal bottle number&lt;\/dcc:content&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:name&gt;\n\u00a0 \u00a0 \u00a0 \u00a0 &lt;\/dcc:identification&gt;\n\u00a0 \u00a0 &lt;\/dcc:identifications&gt;\n&lt;\/dcc:measuringEquipment&gt; "}],"skos:broader":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/2"],"skos:related":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/90"]}