{"@context":{"dc":"http:\/\/purl.org\/dc\/elements\/1.1\/","skos":"http:\/\/www.w3.org\/2004\/02\/skos\/core#","skos:broader":{"@type":"@id"},"skos:inScheme":{"@type":"@id"},"skos:related":{"@type":"@id"},"skos:narrower":{"@type":"@id"},"skos:hasTopConcept":{"@type":"@id"},"skos:topConceptOf":{"@type":"@id"}},"@id":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/384","@type":"skos:Concept","skos:prefLabel":{"@language":"en-US","@value=":"isFunctionalTest"},"skos:inScheme":"https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/","dct:created":"2026-02-20 11:18:16","skos:definition":[{"@lang":"en-US","@value":"functional test "},{"@lang":"de","@value":"Funktionstest "}],"skos:scopeNote":[{"@lang":"en-US","@value":"Calibration primarily serves the metrological traceability of one or more measured quantities. Simultaneously, measuring instruments or artifacts are subjected to extensive functional tests to determine their properties or to ensure conformity with manufacturer specifications, normative requirements, or other user specifications. This can include, for example, information on insulation resistance, stability, hysteresis, self-heating, or inhomogeneity in temperature sensors; the total harmonic distortion of an acoustic calibrator; the input matching or background noise of a signal generator or vector network analyzer; etc. \u2013 which is required as additional information in the calibration certificate but is not suitable for traceability to SI units.\nIn some cases, results of functional tests must be documented in the calibration certificate as necessary supplementary information on procedures, in accordance with ISO\/IEC 17025:2017 7.8.2.1. "},{"@lang":"de","@value":"Die Kalibrierung dient in erster Linie der metrologischen R\u00fcckf\u00fchrbarkeit einer oder mehrerer Messgr\u00f6\u00dfen. Gleichzeitig werden Messger\u00e4te oder Artefakte umfangreichen Funktionstests unterzogen, um deren Eigenschaften zu bestimmen oder Konformit\u00e4t in Bezug auf Herstellerspezifikationen, normative Anforderungen oder sonstige Anwendervorgaben sicherzustellen. Dies k\u00f6nnen beispielsweise Angaben eines Isolationswiderstands, einer Stabilit\u00e4t, einer Hysterese, einer Eigenerw\u00e4rmung oder einer Inhomogenit\u00e4t bei Temperatursensoren, der Klirrfaktor eines Schallkalibrators, die Eingangsanpassung oder Grundrauschen eines Signalgenerators oder eines Vektor-Netzwerk-Analysators, ... sein - die als zus\u00e4tzliche Information im Kalibrierschein gefordert sind, aber nicht zur R\u00fcckf\u00fchrung auf SI-Einheiten geeignet sind.\nErgebnisse von Funktionstests m\u00fcssen in einigen F\u00e4llen gem\u00e4\u00df ISO\/IEC 17025:2017 7.8.2.1 als notwendige Zusatzinformation zu Verfahren im Kalibrierschein dokumentiert werden. "}],"skos:historyNote":[{"@lang":"en-US","@value":"2026-02-20 Created "},{"@lang":"en-US","@value":"2026-03-12 Deleted true from dcc:statement "}],"skos:note":[{"@lang":"de","@value":"VDI\/VDE\/DGQ\/DKD 2622 Blatt 1.1 "}],"skos:example":[{"@lang":"de","@value":"&lt;dcc:statement id=\"functionalTest\" refType=\"basic_isFunctionalTest\"&gt;\n\u00a0 \u00a0&lt;dcc:norm&gt;VDI\/VDE\/DGQ\/DKD 2622-1.1:2025-07&lt;\/dcc:norm&gt;\n\u00a0 \u00a0&lt;dcc:link&gt;https:\/\/www.vdi.de\/mitgliedschaft\/vdi-richtlinien\/details\/vdivdedgqdkd-2622-blatt-11-kalibrieren-von-messmitteln-fuer-elektrische-groessen-grundlagen-kalibrier-und-anzeigemessgroessen&lt;\/dcc:link&gt;\n\u00a0 \u00a0&lt;dcc:declaration&gt;\n\u00a0 \u00a0 \u00a0 &lt;dcc:content lang=\"de\"&gt;Zus\u00e4tzlich zu den Kalibrierergebnissen enth\u00e4lt dieser Kalibrierschein Funktionstests, die einen Einfluss auf die Messunsicherheit der Kalibrierergebnisse haben k\u00f6nnen. Die Funktionstests sind markiert und nicht geeignet, um eine weitere metrologische R\u00fcckf\u00fchrbarkeit zu erm\u00f6glichen. Sie haben das Ziel, zus\u00e4tzliche Anforderungen an den Kalibriergegenstand zu verifizieren (z. B. technische Standards, Kundenanforderung, Herstellerspezifikation).&lt;\/dcc:content&gt;\n\u00a0 \u00a0&lt;\/dcc:declaration&gt;\n&lt;\/dcc:statement&gt;\n&lt;dcc:measurementMetaData&gt;\n\u00a0 \u00a0&lt;dcc:metaData refId=\"functionalTest\"&gt;\n\u00a0 \u00a0 \u00a0 &lt;dcc:validXMLList&gt;true true true&lt;\/dcc:validXMLList&gt;\n\u00a0 \u00a0&lt;\/dcc:metaData&gt;\n&lt;\/dcc:measurementMetaData&gt; "}],"skos:broader":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/2"],"skos:related":["https:\/\/digilab.ptb.de\/dkd\/refType\/vocab\/skos\/107"]}