{"tema_id":"1746","string":"significant fault           #00741","created":"2022-12-19 09:13:39","code":null,"notes":[{"@type":"Cataloger's note","@lang":"en-EN","@value":"reference: R060:2000 2.4.14 "},{"@type":"Cataloger's note","@lang":"en-EN","@value":"ID: 00741 "},{"@type":"Definition note","@lang":"en-EN","@value":"Fault greater than the load cell verification interval, v. The following are not considered significant faults, even when they exceed the load cell verification interval, v: \u2022 faults arising from simultaneous and mutually independent causes; \u2022 faults implying the impossibility to perform any measurements; \u2022 faults being so serious that they are bound to be noticed by all interested in the result of measurement; and \u2022 transitory faults being momentary variations in the load cell output which cannot be interpreted, memorized or transmitted as a measurement result "}]}